Service manual

© 2013-2015, Cornelius Inc. - 18 - Publication Number: 620058442
Quest Elite QLT 2000
Semi-Annually - Clean the Water Inlet Strainer
1. Pull the AC plug from the wall outlet
2. Remove the right side panel from the dispenser.
3. Turn off the water supply to the dispenser.
4. Remove the access port from the “Y” shaped water inlet solenoid
lo
cated on the right side of the dispenser.
5. Clean and reinstall the stainless steel water strainer.
Annually - Cleaning the cabinet
The cabinet bottom surface and walls should be inspected and cleaned annually following the instructions below.
1. Remove natural rubber nozzle bushing gasket
and inspec
t it and Silicone RTV.If cracked,
cleam off RTV and re-apply using kit P/N
729011013 per instructions provided with the
Kit.
2. Re-apply nozzle bushing gaskets so that the
ed
ges lie flat ont the floor of the cabinet.
3. Clean the cabinet floor and w
alls of any spilled
juice and let dry. Use a mild soap/detergent
and plain water.
4. Re-install the pump platform in the reverse
or
der given above.
For more information, refer to the Planned Maintenance Cards found in the Appendix of this Manual.
Daily maintenance tasks
BE 20 D1Flush orange juice system.
Weekly maintenance tasks
BE 20 W1Sanitize orange juice system.
BE 20 W2Check orange juice Ratio.
Monthly maintenance tasks
BE 20 M1Clean condenser filter.
Figure 55.
Figure 56.