Service manual

560001279SER 57
18. Press SIDE 1 “BLEND ON/OFF” switch to prevent more sanitizing solution from entering the product
blender tank.
19. Place waste container under No. 1 dispensing valve nozzle. Open the dispensing valve and dispense all
sanitizing solution from the freeze cylinder. As sanitizing solution level lowers in the freeze cylinder, partially
close the valve to avoid spurting.
20. Place waste container under the No. 1 product blender tank product sample valve. Slowly open the valve
and purge remaining sanitizing solution out of the tank, then close the valve.
21. Syrup Tank System.
A. Disconnect sanitizing solution tank from No. 1 syrup system.
B. Connect syrup tank containing syrup into No. 1 syrup system.
Bag-in-Box Syrup System.
A. Remove end of No. 1 syrup pump syrup inlet line from pail of sanitizing solution.
B. Remove empty bag-in-box connector from No. 1 syrup pump syrup inlet line.
C. Connect No. 1 syrup pump syrup inlet line to bag-in-box containing syrup.
22. Press SIDE 1 “SYRUP PRIME” switch to fill No. 1 syrup system syrup float switch with syrup.
23. Press SIDE 1 ‘‘BLEND ON/OFF’’ switch to fill No. 1 product blender tank with product. Carbonator water
pump will start and begin pumping carbonated water into the product blender tank along with syrup to
make product.
WARNING: Flush residual sanitizing solution from the syrup system as instructed.
Residual sanitizing solution left in the syrup system could create a health hazard.
24. After carbonator water pump cycles off, completely fill No.1 freeze cylinder with product by repeatedly
pulling and releasing the faceplate relief valve and until product comes out of the relief valve port. Open the
dispensing valve until product flows from the valve, then close the valve. Open No. 1 system product
sample valve until product flows from the valve, then close the valve.
25. Press SIDE 1 “MOTOR” switch to start No. 1 freeze cylinder beater. Allow beater to operate for 5-minutes,
then press SIDE 1 “OFF” switch to stop the beater.
26. Syrup Tank System.
A. Disconnect syrup tank containing syrup from No. 1 syrup system.
B. Connect empty syrup tank into No. 1 syrup system.
Bag-in-Box Syrup System.
A. Disconnect No.1 syrup pump syrup inlet line from bag-in-box containing syrup.
B. Install connector from empty bag-in-box on No. 1 syrup pump syrup inlet line.
27. Hold waste container under the dispensing valve and dispense until all product has been dispensed from
the freeze cylinder. As product level lowers in the freeze cylinder, partially close the valve to avoid spurting.
28. Place waste container under No.1 system product sample valve. Slowly open the valve and purge
remaining product out of the product blender tank, then close the valve.
WARNING: To avoid possible injury or property damage, do not attempt to remove the
empty syrup tank cover until CO
2
pressure has been released from the tank.