Electrical Requirements
Refer to the nameplate to determine the power requirements before connecting
electrical power to the unit. All of the power cords shall comply with safety
requirements outlined in the EC Standards (EN60335-1 1 Clause 24.1) in
countries where CE compliance is required. All cords must be HD 21 or HD 22.
Line Voltage
The recommended line voltage range for the Viper unit is 215 to 245VAC.
Measure the voltage at the wall outlet to verify proper wiring of the outlet before
plugging the Viper unit in.
Power
The power circuit must have some sort of overload protection, such as a circuit
breaker or fuse that meets local and national electrical codes. Table 1 shows the
power requirements for the various types of units.
Power Cord
Syrup, Water and CO2
Input Lines
Table 1
2-Barrel 60Hz 3-Barrel 60Hz 2-Barrel 50Hz 3-Barrel 50Hz
20 A. Circuit 30 A. Circuit 20 A. Circuit 30 A. Circuit