© 2008-2009, IMI Cornelius Inc. - 21 - Publication Number: 621260373INS
When the sleep and wakeup settings are complete, press the BACK button to
save the settings and return to the Select menu, shown in Figure 11.
Setting Viscosity
The viscosity maintained in the freeze barrels depends on the type of product
being served. Some products are served best at a higher viscosity, while others
require a lower viscosity for best quality. The Viscosity menu allows the user to
adjust the viscosity in each barrel to the optimum setting for each type of syrup.
Refer to for Table 12 recommended settings based on syrup type.
To set all barrels in the system to the same viscosity setting, follow Table 10, and
then press the ALL button at the bottom of the display while highlighting the
viscosity setting you desire for all the barrels.
Figure 16
When the viscosity settings are complete, press the BACK button to save the
settings and return to the Select menu, shown in Figure 11.
Refer to the service manual for other controller functions and features.
10 Set Wakeup day/time Repeat Steps 5 through 7.
11 Save the WAKEUP
setting
Press the BACK button at the bottom of the
display to save the wakeup setting.
Table 9
Step Action Procedure
Table 10
Step Action Procedure
1 Set viscosity range From the Setup menu (Figure 11), open the
Viscosity Setup menu, shown in Figure 16
2 Select barrel Use the up and down arrows to highlight the
desired barrel.
3 Set range Use the + or - buttons at the bottom of the dis-
play to set the desired range.
4 Select barrel Repeat Steps 2 and 3 for each barrel in the
machine.
VISC
SETUP
12:51P
MAR 04
#1 VISC RANGE 4 40-96
#2 VISC RANGE 5 44-103
BACK ALL - +