Installation manual

Viper Installation Manual
Publication Number: 621360041TBINS - 24 - © 2010-2012, IMI Cornelius Inc.
Pressurizing the Water System
Perform the procedure in Table 14. to verify the water connection to the unit.
Figure 18.
NOTE: Remove the valve cover to access syrup and water valves.
Table 14.
Step Action
1 Turn on the water supply to the unit.
2 Check the system for leaks.
3 The Do Not Drink and Out of Product lights remain on. NOTE: The H2O Out
error does not clear until CO
2 pressure is applied.
4 Turn the product supply valve to the down (BRIX) position and open the
valve at the end of the sample tube.
5 Place the end of the tube in a bucket.
6 Manually lift the water valve at the front of the unit (Figure 18.) to fill the
water system.
7 When water flows from the sample tube, the system is full and you may pro-
ceed to Table 12. and pressurize the CO
2 system.
8 Repeat Steps 4 through 7 for each barrel in the unit.
Manual
Water
Valve
Manual
Syrup
Valve
(pushuptoopen)