ICE FROST Post-Mix and Pre-Mix Installation, Service, and Operator's Manual

Ice Frost Operator’s Manual
© 2004-2006, IMI Cornelius Inc. - 27 - Publication Number: M620919596OPR
Problem Possible Cause Solution
Cap is leaking The nut is loose Tighten the nut
Bowl not refilling Out of syrup
Out of CO
2
Valves are shut off or blocked
Foam covering probes
Fill Switch in off position
Defective syrup pressure switch
• Defective CO
2
shut off
• Replace
• Replace
• Open
• Wait
• Turn on
• Replace
• Replace
Bowl is overfilling Bad Pressure and Levels Card Replace the card
CO
2
leaking from back of unit Proper function of bowl over
pressure discharge solenoids
• Poor connection
If not continuous leak it is nor-
mal operation
• Repair leak
WARNING: Relief valve venting is normal, a continuous leak is not and must be corrected immedi-
ately. Repair the solenoid valve.