Service manual
Quantum Series Installation and Service Manual
© 2002-2010, IMI Cornelius Inc. - 7 - Publication Number: 85289
CONCENTRATE LOADING AND BRIXING
PLACING CONCENTRATE PRODUCTS ON DISPENSING PLATFORM
To engage the concentrate container, place it in the desired position and press down into bottle adapter opening
on dispensing platform tray (inside the cabinet).
NOTE: Make sure o-ring seal on the container adapter is lubricated; otherwise, you may experience
difficulties with container replacement.
NOTE: Concentrate in the containers must be completely thawed and be within the temperature range
of 35°F
- 40°F (1.6°C - 4.4°C). Failing to supply concentrate inside the recommended tempera-
ture range, especially below 35°F (1.6°C), will cause an out of brix drink.
It is recommended the concentrate be thawed in a refrigerated (35°F - 40°F) (1.6°C - 4.4°C) compartment for 36
to 48 hours before use.
It is recommended that the thawed concentrate be thoroughly shaken before use.
CHANGING CONCENTRATE FLAVOR
1. Perform flush cycle
2. Move valve handle to “Dispense” position
3. Replace concentrate container
PUMP PRIMING
1. Follow instructions in paragraph “Placing Concentrate Products on the Dispensing Platform”
2. Close the door (or unit will not activate)
3. Depress the push button until concentrate appears at the dispensing nozzle.
BRIX SETTING
1. Make two (2) full clockwise turns of the corresponding brix knob from the “all the way out” position (factory
set). These two turns will bring you within one turn of proper brix setting. (Refer to brix table located on the
inside of the refrigerated compartment door).
2. Dispense 1/2 cup of juice and discard.
3. Dispense 1/2 cup of juice and use refractometer to check brix level.
4. Clockwise rotation of the knob decreases brix level for example from 13% to 11.5%. Counterclockwise will
increase brix level for example from 11.5% to 13%.
If a brix problem is experienced, refer to troubleshooting guide.