Service manual
Quantum Series Installation and Service Manual
Publication Number: 85289 - 10 - © 2002-2010, IMI Cornelius Inc.
7. While holding the pump halves together by hand, reinsert the four thumb screws and tighten them in a
criss-cross pattern until the two halves are pressed together.
8. Insert the two stainless tubes into the hose ends and fasten them with new clamps using pliers to tighten
the clamps.
IMPORTANT: Replace platform in unit, reinstall nozzles and static mixers, connect water, install
product shelf and concentrate, and reconnect power to unit.
Figure 1.
Flush Lever
Juice Inlet
Stainless Steel
Concentrate Delivery
Tub es
BRIX
Adjusting
Screw
Hose Clamps
Pump Tubing
Thumb Screws
Rear Pump Half
Water Inlet
w/ Quick Connect
Quick Connect
Actuator
Removable Pump Platform
Mixed Product
Outlet
Latch