Service manual

Quantum Series Installation and Service Manual
© 2002-2010, IMI Cornelius Inc. - 5 - Publication Number: 85289
INSTALLATION SPECIFICATIONS
WATER SUPPLY
The Quantum Juice Dispensing machine is designed to dispense juice at a high flow rate. It is very important that
the incoming water line is dedicated for the unit, or at least does not have other machines connected which could
cause a water surge; i.e., a dishwashing machine.
NOTE: For increased cooling capacity the unit should be connected to a remote recirculating cooling
unit. If the location is equipped with a dedicated beverage water supply system the juice dis-
penser should be connected to it.
NOTE: The water supply should be consistent with proper water quality standard (neutral ph of 7.0 to
8.0), and should not be connected to a water softener. The water cooling coil is Copper, and
may be affected by poor water conditions (i.e. severe corrosion and pitting).
!
WARNING:
This equipment must be installed to comply with the International Plumbing Code of the International Code
Council and the Food Code Manual 01 the Food and Drug Administration (FDA). For models installed outside the
U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area.
Failure to comply could result in serious in jury, death or damage to the equipment.
Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained according to Federal, State and Local laws.
ELECTRICAL
A minimum of 15 amps electrical service is needed for 120V power supply or 10 amps for 220V supply.
SPACE
The minimum clearance is: 4” (10.16cm) in back and 12” (30.48cm) on top and open to the front if sides are
blocked off. If the sides are open then only 2” (5.08cm) is required in the back. Space between the bottom of the
unit and the counter cannot be obstructed.
NOTE: Condenser air is drawn from the bottom and discharged out the back. Failure to maintain clear-
ance space will reduce capacity of the unit and cause premature compressor failure.
CONNECTING WATER SUPPLY
1. Secure 3/8” (0.95cm) flexible hose to the unit water inlet. Make sure that the seal washer is used (hose and
seal washer are included with the installation kit).
2. When securing flare nut use backup wrench on male side of the fitting (unit side) to prevent twisting of the
copper tube inside the unit and/or possible damage to the water strainer/solenoid. A water shut off outside
the unit is recommended.
FILLING UNIT WITH WATER
To properly prime the unit with water, without air pockets in the system, push the dispensing switches
simultaneously for a few seconds each. Repeat above until a steady flow of water is observed.
NOTE: Water splashing may occur during the purge cycle.
FLUSHING AND SANITIZING ON START UP
Follow standard sanitizing and flushing procedure.