Service manual

Quest Installation and Service Manual
720506904 - 7 - Revision B
5. To change the brix setting, simply readjust the water flow rate. Locat-
ed on each of the valve assemblies inside the refrigerated compart-
ment are the adjusting screws for the water flow rate (one per valve).
If the brix reading is too high or low, rotate the appropriate water flow
control according to the diagram below. Repeat steps 1-5 until the brix
setting is achieved.
IMPORTANT: When making changes to the water flow control, do not rotate more
than 1/4 turn per adjustment. Additionally, prior to taking your next brix reading,
“tap” the corresponding dispense button several times prior to drawing a sample.
This will clear remnant drink from the dispense nozzle AND help move the flow con-
trol to its new setting.
Lowers Brix by increasing water
Raises Brix by reducing water