TROUBLE-SHOOTING
GUIDE
The following pages contain trouble-shooting information intended to aid an experienced service
person in diagnosing operational problems that may occur. For further assistance, contact the IMI
Cornelius Technical Services department at 1-888-248-5568 (630-539-6850 outside the United
States) between the hours of 7:30A.M. and 5:00P.M. Central Standard Time. You must have the
model and serial number (Located on the right side of the dispenser) prior to calling.
PROBLEM PROBABLE CAUSE REMEDY
Totally Inoperative No power to dispenser due to
tripped circuit breaker
Reset circuit breaker. Confirm
that breaker is correct size and
no other equipment is operating
on the same circuit. Also confirm
that supply voltage is +/- 10% of
nameplate specifications.
Loose or broken power supply
connection inside dispenser.
Repair connection.
No cooling Line voltage is not within +/- 10%
of nameplate specifications caus-
ing compressor overload to trip
Contact an electrician
No water in water ice bath or
water level extremely low expos-
ing the ice bank sensing probe
Fill ice bath to proper water level
Defective Ice Bank Control or
sensing probe
Replace
Cabinet fan is inoperative result-
ing in warm concentrate (water
continues to cool)
Replace
Compressor short cycles on
overload
Excessively high discharge pres-
sure due to restricted condenser
or inoperative condenser fan
motor
Compressor starts but hums and
trips overload
Seized or shorted compressor,
replace
Defective compressor overload
or start capacitor
Test and replace
Compressor starts but does not
switch off of start winding
Relay or compressor is defective.
Test and replace faulty item
Refrigerant leak Repair leak, evacuate and
recharge system
No water dis-
pensed, concen-
trate only
No water to dispenser Restore Water
Water supply line inside refriger-
ated cabinet disconnected from
pump platform
Reconnect