Warm Drink Ambient air around dispenser is
too warm
Relocate dispenser
Excessive demand on dispenser Add water pre-cooler or second
dispenser
Dirty condenser coil Clean condenser coil
Inoperative condenser fan Replace condenser fan motor
Defective Ice Bank Control Test and replace if necessary
Loss of refrigerant charge due to
leak in system
Repair leak and recharge system
Water continuous-
ly drips from noz-
zle when in OFF
mode
Main water solenoid at base of
unit or water solenoid on pump
platform not shutting off tightly
Clean solenoid(s), replace parts
as necessary (refer to the
Planned Maintenance Section)
Concentrate
warm, water cold
Cabinet fan inoperable Check/replace fan
Agitator motor/pump inoperable
or restricted
Check/replace agitator motor
Loss of refrigerant charge due to
leak in system
Repair leak and recharge system
Brix Problem Water supply pressure too low,
less than 20 psi (1.4 bar) flowing
water pressure fluctuates sharply
Correct water supply problem to
ensure a constant 40 psi (3 bar)
flowing to the dispenser
Water flow control binding or
spring is defective
Clean and/or replace parts as
necessary
Improperly thawed concentrate.
Brix changes as the concentrate
temperature changes (concen-
trate becomes thinner as temper-
ature rises)
Concentrate should be 35-40°F
(1.7-4.5°C) prior to loading
Pump Inoperative Pump motor defective 28VDC should be present at
pump motor during dispense. If
voltage is present and motor
does not start, replace pump
motor
No power to transformer or no
28VAC output from transformer
Confirm transformer has line volt-
age present on primary side. If no
28VAC output from the second-
ary replace transformer
Defective voltage regulator board
(VRB) located inside front electri-
cal box
Confirm board produces 28VDC
present when the dispense but-
ton is pressed (refer to the Elec-
trical Box Wiring Diagram for
VDC output location). Replace
VRB if necessary
Defective dispense control board
(Push button or portion control)
Test and replace if necessary
PROBLEM PROBABLE CAUSE REMEDY