Service manual

Quest Elite 4000 Service Manual
© 2010-2015, Cornelius Inc. - 17 - Publication Number: 620048956SER
Figure 14. Interior Details
5. Slide the locking latch forward. Lift the platform slightly and pull forward to
gain access to the electrical connector (see Figure 14).
6. Unplug the electrical connector by squeezing the locking tabs on either side and
pulling out the connector. Lift and remove the pump platform (see Figure 14).
Replacing the Tubing When the pump platform has been removed, replace the tubing by performing the
following procedure.
1. Remove the two white plastic hose clamps from the pump tube connections
(See Figure 14) and remove the concentrate delivery tubes from the hose ends.
2. Loosen and remove the four screws from the pump body (See Figure 15).
Front & Rear
Pump Halves
Pump Motor
Water Manifold
Water Solenoid
Locking Latch
Bottle Adapter
Juice Inlet
Water Inlet
Quick Connector
Pump Body Screws
BRIX Adjustment Screw
Concentrate
Delivery Tubes