ICE DISPENSER MODELS: TJ45 TJ90 Operator’s Manual Part No. 90614 Revision: H Revision Date: May 26, 2014 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment â REMCOR INC: PRINTED IN U.S.
TABLE OF CONTENTS Page SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OPERATOR INSTRUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY PRECAUTIONS Always disconnect power to the dispenser before servicing or cleaning. Never place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when the dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice.
INSTALLATION INSTRUCTIONS 1. * Locate the dispenser indoors on a level counter top, unpack 4 legs and install them into the threaded holes provided in the bottom of the unit. 2. Connect 3/4”IPS (or equal) drain line to the 3/4”threaded drain connections at the lower rear of the unit. This line must pitch downward to an open drain, and must contain no traps, or improper drainage will result. 3. Clean the hopper interior (see cleaning instructions). 4. Connect the power cord to a 120 volt, 60 Hz.
OPERATOR INSTRUCTION OPERATING INSTRUCTIONS Fill the hopper with ice and replace the lid. Pushing the dispense lever will cause ice to flow from the ice chute. Ice flow will continue until the lever is released. If ice does not dispense, see the “Troubleshooting Guide”to find the cause CAUTION: Use caution to avoid spilling ice when filling dispenser. immediately Clean up any spilled ice from filling or operation of the unit.
MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated: DAILY or as required Remove foreign material from the vending area sink to prevent drain blockage. WEEKLY or as required Clean vending area. Check for proper water drainage from the vending area sink. MONTHLY Clean and sanitize the hopper interior (see CLEANING INSTRUCTIONS). If the dispenser fails to dispense ice when operated, check that the hopper has ice in it and that power is being supplied to the unit.
TOUBLESHOOTING IMPORTANT: only qualified personnel should service internal components. Should your unit fail to operate properly, check that the electric plug is secure, and that the hopper contains ice. If the unit still does not dispense, check the following chare under the appropriate symptoms to aid in locating the defect. Trouble Probable Cause BLOWN FUSE OR CIRCUIT BREAKER. GATE DOES NOT OPEN. AGITATOR DOES NOT TURN. GATE DOES NOT OPEN OR IS SLUGGISH. AGITATOR TURNS. GATE OPENS.
1 5/8-IN 15 7/8-IN 12 5/8-IN 1 5/8-IN TJ45 21 25/32-IN 18 9/16-IN 3/4-IN DIA. OUTLINE OF UNITS 1 5/8-IN 22-IN 18 3/4-IN 1 5/8-IN TJ90 27 23/32-IN 24 1/2-IN FIGURE 1.
SERVICE INFORMATION DANGER: ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT. GATE SOLENOID N THERMOSTAT WHT RED LIGHT BLK WHT BLK WHT 1¼ AMP.
4 12 19 15 14 10 1 8 11 9 FIGURE 3 UPPER SECTION EXPLODED VIEW TJ45 16 5 2 3 6 7 13 17 FIGURE 4 EXPLODED VIEW LOWER SECTION TJ45 90614 8
4 10 11 12 14 1 15 9 19 8 18 FIGURE 5 EXPLODED VIEW UPPER SECTION TJ90 16 5 2 3 6 7 13 17 FIGURE 6 EXPLODED VIEW LOWER SECTION TJ90 9 90614
PARTS LIST Item No. Part No. TJ45 Part No.
1 2 22 4 3 5 4 22 6 19 18 22 20 21 8 16 15 14 11 10 17 19 13 9 12 7 FIGURE 7. SOLENOID ASSEMBLY Index No. Part No. Qty. Name 1 21493 1 2# 31551 1 Solenoid Mounting Plate Solenoid Service Kit 3 70171 2 8--32 x 3/8 Phil Tr HD Screw 4 70121 2 No.
CORPORATE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 708. 980.