Corning Optical Communications User Manual I CMA-490-AEN I Page 81
7 APPENDIX A: SPECIFICATIONS
7.1 Supported Services
Technology
Frequency Range (MHz)
Service/Band
Uplink (UL)
Downlink (DL)
LTE 2600 2500-2570 2620-2690
GSM/UMTS/LTE GSM 880-915 925-960
LTE 800L 791-821 832-862
GSM/UMTS/LTE DCS 1710-1785 1805-1880
UMTS/LTE UMTS 1920-1980 2110-2170
7.2 MRU Coupling Specifications
7.3
Optical
Optical Output Power
< 9 dBm
Max. Optical Budget
7 dB (5 dB over any temp, and optical variations)
Back Reflectance
- 60 dB
Optical Connector
OIM: Female MTP
®
connector
MRU: LC APC SM
Fiber Type
Corning
®
SMF-28
®
fiber or compatible
Wavelength
1310 ± 10nm (@ 25
◦
C)
DL Center Frequency of
Supported Bands (MHz)
Typical Coupling* (dB)
942.5 26.0
847 26.0
1842.5 26.0
2140 26.0
2655 26.0
*The typical coupling value for the supported bands is -26 dB however a delta of +/- 3 dB can be expected. As such, the actual coupling value for each unit
(measured for the DL center frequency of supported bands) is specified on a label on the unit. Note that the test port is bi-directional, so that an UL signal