User's Manual
Table Of Contents
- 1 Introduction
- 2 Unit Descriptions
- 3 Installation Guidelines
- 3.1 General System Specifications and Requirements
- 3.2 Infrastructure Preparation
- 3.3 Antenna Specifications and Guidelines
- 4 IHU Installation
- 4.1 General Installation Information
- 4.2 IHU Installation
- 4.3 Grounding Chassis
- 4.4 RF Connections
- 4.5 IHU Fiber Connections
- 4.6 Management Connections
- 4.7 Power Connections and Power Up
- 4.8 Verifying Normal Operation
- 5 PSU6 Installation
- 6 MRU Installation
- 7 Appendix A: Specifications
- 8 Appendix B: Ordering Information
Corning Optical Communications DRAFT User Manual I CMA-XXX-AEN I Page 30
3.1.2 Power and Heat Specifications Summary
Table 3-3 provides the power, heat and rack specifications for the equipment installed in the headend/telco rooms.
Unit
Description
Min-Max Voltage (VAC)
Max Power Draw
(Watts)
No. of
Units
Heat (BTU/hr)
IHU Integrated headend unit 100 – 220 300 1 1020
PSU6 Six Unit DC power supply unit
85 to 265
1200
(100 W per port)
1 512
(typical at 100 V in)
Table 3-3. Power and Heat Specifications
3.1.3 Dimensions, Weight and Rack Specifications of Units
Table 3-4 describes the physical specifications of the Corning
optical network evolution (ONE
™
) solution units described in this
manual.
Unit
Dimensions (H x W x D)
Rack Space
19-in (RU)
Weight: lbs [kg]
IHU 7 x 17.3 x 15.5 in
[177.8 x 440 x 394 mm]
4 Chassis: 30 lbs (14 kg)
Per RIM: 1.9 lbs (0.9 kg)
Per RIX: 1.54 lbs (0.7 kg)
Per OIM: 1.5 lb (0.7 kg)
Per OIX: 1.54 lb (0.7 kg)
ACM: 2.2 lb (1.0 kg)
PSM: 1.98 lb (0.9 kg)
PSU6 1.73 x 17.51 x 13.74 in
[44 x 445 x 349 mm]
1
Enclosure: 6.22 lb (2.825 kg)
Per PSM-I module: 0.8 lb (0.36 kg)
MRU
10.5 x 17.5* x 15.75 in (266.7 x 445 x 400 mm)
*without rack brackets
6
Chassis without PAMs: 48 lbs (21.8 kg)
Each PAM: 4.7 lbs (2.15 kg)
Table 3-4. Dimensions, Weight and Rack Specifications of Headend/Intermediate Units
3.2 Infrastructure Preparation
The following installation rules are based on the assumption that the site survey and installation planning (including power
requirements) have been completed.
3.2.1 Site Considerations
• The distance between the MRU service antenna and the coverage area should correspond to line of sight (LoS)
requirements for maximum coverage area.
• The maximum fiber path loss is 5 dB.
• The system delay of the optical system must be taken into consideration when there are neighboring BTS sites overlapping
in coverage.