User's Manual

Table Of Contents
Corning Optical Communications DRAFT User Manual I CMA-XXX-AEN I Page 44
4.2.6.2 Installing the Chassis Modules
To install modules
1. Remove blank panels of relevant slots
2. For modules with ejectors (i.e. RIM, OIM, expander modules, FMM/FRM and control module) - ejectors should be
completely open when inserting in dedicated slot. Figure 4-15 and Figure 4-16 show examples of module type captive
screws and ejectors.
3. Slide modules in the relevant slots (refer to module locations described in Table 4-2 and then push in until it clicks into the
backplane.
4. (Where relevant) close ejectors and on all modules, tighten captive screws. Figure 4-15 and Figure 4-16 show examples of
module type captive screws and ejectors.
Figure 4-15. Control Module Ejectors and Captive Screws Figure 4-16. RIM Ejectors and Captive Screws
4.3 Grounding Chassis
Grounding connections are the same foe all chassis types.
Connect the ground via the two-hole, standard barrel grounding lug
located on the chassis rear panel (see Figure 4-17):
Use stranded copper wire conductors
10-14 AWG
Holes - 1/4 inch
Figure 4-17. Grounding Lug (Chassis Rear)
4.4 RF Connections
4.4.1 RIM Connections to RF Source