User's Manual

Table Of Contents
Corning Optical Communications DRAFT User Manual I CMA-XXX-AEN I Page 50
4.8 Verifying Normal Operation
After powering up, verify that the HCM/ACM LEDs (see Figure 4-28) indicate normal operation. If the RF source is operational,
also verify that the RIM LEDs (see Figure 4-30
) indicate normal operation.
Note: The LEDs are the same for HCM and ACM modules.
HCM LED Description
PWR Steady green - power input detected by module.
RUN Blinking green – module software up and running
SYS Steady green - overall status of the managed system
is OK
FAN Steady green normal operation status for all fans
Table 4-3. HCM/ACM LED Descriptions
Figure 4-28. HCM/ACM LEDs
LED Description
PWR Steady green - power input detected by module.
RUN Blinking green – module software up and running
SYS Steady green - overall status of the managed system
is OK
FAN Steady green normal operation status for all fans
Table 4-4. ACM LED Descriptions
Figure 4-29. HCM/ACM LEDs
RIM LED Description
Protect N/A
DL High Off - DL RF input level in threshold range
Steady red DL RF input level is 3 dB above
maximum expected power
DL Low Off - DL RF input level in threshold range
Steady Red - DL RF input level is 15 dB below
maximum expected power
RUN Blinking green - RIM module software has initialized
and is up and running
Off power off
PWR Steady green - input power is within required range
Table 4-5. RIM LED Descriptions
Figure 4-30. RIM LEDs