User's Manual

Table Of Contents
Corning Optical Communications User Manual I CMA-490-AEN I Page 54
5.1.3 Mounting PSU6
The PSU6 can be mounted in 19-in communication rack or on a wall appropriate brackets provided for both mounting options.
5.1.3.1 Rackmount
Mount the PSU6 in the 19-in communication rack and secure the rack brackets to the rack uprights using appropriate rack
screws.
5.1.3.2 Wall Mount
To mount the PSU6 on a wall
1. Remove the rack mounting brackets and set the screws aside.
Figure 5-3. PSU6 Rack Bracket(s) for Removal
2. Using the four screws (previously set aside), assemble the wall mount brackets onto the sides of the PSU6 so that the unit
can be mounted belly-to-wall. See Figure 5-4.
Figure 5-4. DC Assembling Wall Mount Brackets
Note the following
The unit should be mounted on the wall with the DC connectors facing sideways. See Figure 5-5.