Installation RF Path Elements CMA-331-AEN Page 134
Draft
5.2.3.3 Locate Required Connection Cables
Locate the following connection cables leading from the cable infrastructure:
DC wiring:
One pair for MAIN POWER connection
One pair for SECONDARY POWER connection (for RAU models including GEM module)
Fiber pairs (Corning
®
SMF-28
®
fiber or compatible):
One fiber pair for RAU module
One fiber pair for GEM module (for RAU models including GEM)
Grounding wire
For RAU5 models not including external antenna RF jumper cables from installed external antenna
5.2.3.4 Bracket Installation and Mounting RAU5
Note the following:
The installation procedure for the bracket provided with the RAU5 refers to wall and concrete ceiling installations. For
additional mounting options refer to Appendix D: RAU5 Mid-Mount Bracket Assembly.
When mounting the bracket on a wall the captive screw (indicated in Figure 5-88) should always be positioned in the same
direction as the RAU5 connectors.
In wallmount installations the connectors should face downwards.
If installing above acoustic ceiling, allow for at least 1 inch above the acoustic ceiling for air flow cooling.
Figure 5-88.Example of (Concrete) Ceiling Installation of Mounting Bracket (RAU5 with External Antenna)