Installation RF Path Elements CMA-331-AEN Page 136
Draft
Figure 5-90. RAU5 pins and Bracket Key-holes
Figure 5-91. Closing Bracket Captive Screw
5.2.3.5 Cables Ground, F/O and RF connections
1. Route the cables located in Section 2.
2. Connect the earth ground to the RAU5 8-32 x 3/8 grounding screw. See Figure 5 for example of RAU5 ground connection.
3. Connect optic fiber pair to RAU5 module LC APC optic connector. See Figure 5-92.
Figure 5-92. GND, F/O and RF Cable Connections
4. If required by site planner perform (QMA) connections to CELL and/or LTE external filters.
Note:
Refer to Quick Installation Sheet (CMA-366-AEN) provided with
700/800 Cavity Filter or download from Corning
Resource Center (Product resources) site.
5. For RAU5 models not including external antennas connect the RAU5 QMA ‘Ext. Ant.’ connector to the external antenna.
Note: Supported external antenna types: vertical, directional or omni-directional antennas. RAU models with RxU module also
require connecting the RxU to external antenna.