Interface Description
MGMT RJ-45 local management connection
MAIN POWER
Main DC input; Input range: 37 57 VDC; DC power fed from composite
cable; Refer to section 1.3.3.1 for power consumption
SECONDARY POWER
Secondary DC input required for use in addition to ‘MAIN POWER’ with PoE
clients (installations including GEM module); Refer to section 1.3.3.1 for
power input per PoE port and consumption
LIST. MODE N/A
EXTERNAL ANTENNA QMA connector for external broadband antenna connection
CELL/LTE FILTER
Two QMA RF connectors (In/Out) per external cavity filter type (i.e. LTE and
CELL)
OPTIC LC APC SM connectors for UL and DL fiber optic connections
GROUNDING BOLT 8-32 x 3/8 grounding screw used for connecting RAU5 to earth ground
Table 2-14. RAU5 Connection Interface Descriptions
LED Description
POWER Steady Green - Power input detected by RAU5
Off - No power supplied to RAU
LINK Steady Green Optical link power to/from the RAU 5is normal
Blinking green Optical power from remote is lower than required
Off No optical link is detected
RUN Blinking Green Blinking RAU5 Initializing
Steady Green RAU5 boot up sequence complete and module SW up
and running
Off No power supplied to unit