User's Manual
Table Of Contents
- Corning
- ONE™ Wireless Platform
- User Manual
- Preface Material
- About This Manual
- Hardware
- Software Warranty
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- Regulatory Compliance Information
- RF Safety
- CAUTION!
- Laser Safety
- Licensee Contact Information
- Additional Relevant Documents
- Table of Contents
- 1 Introduction
- Figure 1-1. Illustration of Precise Service Distribution over Selected Remote Areas
- Table 1-17. Ethernet Path Units
- Figure 1-2. Corning ONE Wireless Platform Basic Architecture
- Figure 1-3. Corning® ONE™ Solution RF Path Architecture
- Figure 1-4. Corning ONE™ Solution Ethernet Path Architecture
- Figure 1-6. Illustration of Service Group Distribution
- Figure 1-7. Single Service Group Configuration
- Figure 1-8. Example of Dual Service Group Configuration
- Figure 1-9. Example of Three Service Group Configuration
- Figure 1-10. Example of Tri-Service Group Configuration with Two HEUs
- Figure 1-11. Example 1 of FMM-to-FRM Service Distribution
- Figure 1-12. Example 2 of FMM-to-FRM Service Distribution
- 2 Unit Descriptions - RF Path
- Figure 2-1. RF Path with HEU and OIU Headend Components
- Figure 2-2. RF Path with IHU Headend Component
- Figure 2-3. Example of HEU with Installed Modules
- Figure 2-4. HCM Module
- Figure 2-5. ACM Module
- Figure 2-6. RIM Module
- Figure 2-7.FRM
- Figure 2-8. RIX Expander Module Interfaces
- Figure 2-9. Expander Termination Module
- Figure 2-10. PSM-AC Power Supply Module
- PSM-DC
- Figure 2-11. DC Power Supply Module
- Figure 2-12. OIU Front Panel with Installed Modules
- Figure 2-13. Optical Interface Module
- Figure 2-14.FMM
- Figure 2-15. OIX Expander Module Interfaces
- Figure 2-16. IHU Front Panel with Installed Modules
- Figure 2-17. RF Path Remote-end Components
- Figure 2-18. ICU Front Panel Interfaces and Modules
- Figure 2-19. ICU Rear Panel Interfaces and PSM Modules
- Figure 2-20. RAU Module Interfaces
- Figure 2-21. RAU LEDs
- Table 2-19. RAU Status LEDs Description
- Figure 2-22. RAU5 Interfaces
- 3 Unit Descriptions - Ethernet Path
- Figure 3-2. CEU Front Panel with Installed CEM Module
- Figure 3-3. CEU Rear Panel
- Figure 3-5. CEM LEDs
- Figure 3-6. GEM Interfaces
- Figure 3-7. GEM LED Description
- Figure 3-8. GEU Enclosure: Top (Left) and Open Underside (Right)
- 4 Installation Guidelines
- Figure 4-1. Example of Communication Rack Installation
- Types of Power Supplies
- 5 Appendix E: Specifications
- RF Parameters for FCM Solution
- Optical Specifications
- Standards and Approvals
- RF Path: Coverage Component Specifications
- Fiber Connectivity Module (FCM) Specifications
- 6 Appendix F: Ordering Information
- HEU and OIU Assemblies and Modules
- Remote Units
- SFP+ Modules
- Ethernet Path Units
- Hardware
- Cable Ordering Information
- Cable Configurations
Introduction
CMA-331-AEN
Page 27
1.4.2 Ethernet Path
The digital services from the corporate LAN (received via Ethernet Switch) are converted to optic signals by the centralized
Ethernet unit (CEU) and routed over optic fibers towards the GEM units. The optical traffic is then converted to 1 GbE by the
Gigabit Ethernet modules (GEM) modules and distributed to two third party equipment such as access points, Ethernet switch,
etc.
Note: GEMs can be connected to the CEU either directly, or via an ICU (described in section
1.4.1 ). In that case, the ICU can
also provide DC to the GEMs.
Figure 1-4. Corning ONE™ Solution Ethernet Path Architecture