User's Manual
Table Of Contents
- Corning
- ONE™ Wireless Platform
- User Manual
- Preface Material
- About This Manual
- Hardware
- Software Warranty
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- Regulatory Compliance Information
- RF Safety
- CAUTION!
- Laser Safety
- Licensee Contact Information
- Additional Relevant Documents
- Table of Contents
- 1 Introduction
- Figure 1-1. Illustration of Precise Service Distribution over Selected Remote Areas
- Table 1-17. Ethernet Path Units
- Figure 1-2. Corning ONE Wireless Platform Basic Architecture
- Figure 1-3. Corning® ONE™ Solution RF Path Architecture
- Figure 1-4. Corning ONE™ Solution Ethernet Path Architecture
- Figure 1-6. Illustration of Service Group Distribution
- Figure 1-7. Single Service Group Configuration
- Figure 1-8. Example of Dual Service Group Configuration
- Figure 1-9. Example of Three Service Group Configuration
- Figure 1-10. Example of Tri-Service Group Configuration with Two HEUs
- Figure 1-11. Example 1 of FMM-to-FRM Service Distribution
- Figure 1-12. Example 2 of FMM-to-FRM Service Distribution
- 2 Unit Descriptions - RF Path
- Figure 2-1. RF Path with HEU and OIU Headend Components
- Figure 2-2. RF Path with IHU Headend Component
- Figure 2-3. Example of HEU with Installed Modules
- Figure 2-4. HCM Module
- Figure 2-5. ACM Module
- Figure 2-6. RIM Module
- Figure 2-7.FRM
- Figure 2-8. RIX Expander Module Interfaces
- Figure 2-9. Expander Termination Module
- Figure 2-10. PSM-AC Power Supply Module
- PSM-DC
- Figure 2-11. DC Power Supply Module
- Figure 2-12. OIU Front Panel with Installed Modules
- Figure 2-13. Optical Interface Module
- Figure 2-14.FMM
- Figure 2-15. OIX Expander Module Interfaces
- Figure 2-16. IHU Front Panel with Installed Modules
- Figure 2-17. RF Path Remote-end Components
- Figure 2-18. ICU Front Panel Interfaces and Modules
- Figure 2-19. ICU Rear Panel Interfaces and PSM Modules
- Figure 2-20. RAU Module Interfaces
- Figure 2-21. RAU LEDs
- Table 2-19. RAU Status LEDs Description
- Figure 2-22. RAU5 Interfaces
- 3 Unit Descriptions - Ethernet Path
- Figure 3-2. CEU Front Panel with Installed CEM Module
- Figure 3-3. CEU Rear Panel
- Figure 3-5. CEM LEDs
- Figure 3-6. GEM Interfaces
- Figure 3-7. GEM LED Description
- Figure 3-8. GEU Enclosure: Top (Left) and Open Underside (Right)
- 4 Installation Guidelines
- Figure 4-1. Example of Communication Rack Installation
- Types of Power Supplies
- 5 Appendix E: Specifications
- RF Parameters for FCM Solution
- Optical Specifications
- Standards and Approvals
- RF Path: Coverage Component Specifications
- Fiber Connectivity Module (FCM) Specifications
- 6 Appendix F: Ordering Information
- HEU and OIU Assemblies and Modules
- Remote Units
- SFP+ Modules
- Ethernet Path Units
- Hardware
- Cable Ordering Information
- Cable Configurations
Unit Descriptions - RF Path
CMA-331-AEN
Page 55
Interface
Description
MGMT RJ-45 local management connection
MAIN POWER
Main DC input; Input range: 37 – 57 VDC; DC power fed from composite
cable; Refer to section
1.3.2.1 for power consumption
SECONDARY POWER
Secondary DC input required for use in addition to “MAIN POWER” with PoE
clients (installations including GEM module); Refer to section
1.3.2.1 for
power input per PoE port and consumption
LIST. MODE N/A
EXTERNAL ANTENNA QMA connector for external broadband antenna connection
CELL/LTE FILTER
Two QMA RF connectors (In/Out) per external cavity filter type (i.e. LTE and
CELL)
OPTIC LC APC SM connectors for UL and DL fiber optic connections
GROUNDING BOLT 8-32 x 3/8 grounding screw used for connecting RAU5 to earth ground
Table 2-20. RAU5 Connection Interface Descriptions
LED
Description
POWER Steady green - power input detected by RAU5
Off - no power supplied to RAU
LINK Steady green – Optical link power to/from the RAU 5 is normal
Blinking green – Optical power from remote is lower than required
Off – no optical link is detected
RUN Blinking green blinking – RAU5 initializing
Steady green – RAU5 boot up sequence complete and module software up
and running
Off – no power supplied to unit
Table 2-21. RAU5 LED Descriptions