MobileAccessGX Installation and Configuration Guide 12
Item Qty. Image
RJ45 Ethernet Communication Cable 1
Key – used for opening unit panels for
access to internal components.
1
3. Check for signs of external damage. If there is any damage, call your MobileAccess service
representative.
2.6.2 Required Tools
The following tools are the minimum required when installing the GX remote unit or performing
routine maintenance:
Allen Key (M5.5)
Electronic Drill
Adjustable Spanner (0.31 inch~0.79 inch)
Philips Screwdriver
2.6.3 Mounting
CAUTION!
MobileAccessGX-40W weighs 99lb, take all necessary precautions when mounting. A
minimum of two people is required for installing GX.
Please note the following:
The GX unit is mounted vertically with the connectors facing downwards
.
Instructions are provided for
concrete
walls and pole mounting.
The same mounting brackets (2) are used for both wallmount and pole mount.
2.6.3.1 Wall Mount Installation
NOTE: The instructions provided in this section are for concrete walls only.
To mount the unit on the wall
1. Select the wall mount location according to the following criteria:
General surroundings
Ventilated and easy-to-reach area (for maintenance and on-site inspection)
Proximity to the antenna in order to minimize cable loss
2. Using the upper and lower brackets for reference (see diagram in
Figure 2-3
)
Measure and mark the location for drilling the (supplied) Masonry mounting bolts in the
wall (2 per bracket and drill the holes.
Drill the holes for the Masonry Bolts.