User's Manual

MobileAccessGX Installation and Configuration Guide 15
Figure 2-7. Mounting Bracket Dimensions
b. Hose Clamps (supplied): Slip two hose clamps through each bracket as shown in
Figure 2-8
tightly secure each bracket to the pole, maintaining a distance of 123.9cm
between bracket
holes
as shown in
Figure 2-7
.
Figure 2-9. Bracket with Hose Clamps
3. Connectors facing downwards, hang the enclosure on to the M8 nuts of the upper and lower
mounting brackets and then pull the whole enclosure downwards to make sure that the hex
bolts firmly fit into the narrow slots of the mounting tabs.
4. Use spanner to tighten hex bolts (M8x12) to mounting bracket to complete the installation.
15cm
123.9cm Insert U bolt throu
g
h here
Insert U bolt through here