MobileAccessGX Installation and Configuration Guide 20
2.7.4 Power Connections
CAUTION!
Any open RF port on GX or improper connection between GX RF ports and combiner
input ports will damage GX internal power amplifier after the equipment is powered on.
Make sure all connections are performed correctly before powering.
For a LOCAL AC connection - connect the supplied power cable to the power supply port
(100-240VAC, 15A maximum).
Figure 2-15. GX AC Power Connection
For a REMOTE DC power connection - refer to following table for remote power wiring
requirements.
AWG mm2 Working
Current (A)
Wire Length
(M)
Power Supply Cable
Voltage (V)
13 2.54 15 30 4
13 2.54 15 50 6.6
13 2.54 15 70 9.3
12 3.14 15 30 3.2
12 3.14 15 50 5.4
12 3.14 15 70 7.6
12 3.14 15 100 10.8
Table 2-1. Remote DC Power Supply Wiring