User's Manual

MobileAccessGX Installation and Configuration Guide 37
2. Mask irrelevant alarm conditions, in both tabs via the Modify button, to avoid having them
reflected overall status of the GX unit (displayed in the
GX Alarms
area).
For Example
In the example below, the
GX Alarms
dialog shows the alarm response if the Service 2 DL
Output Power Low alarm is NOT masked (enabled). In that case the
Service 2
and
Overall Status
will be RED indicating a fault.
If the Service 2 alarm is MASKED (Disabled), then the LED for the alarm will be RED; but,
the corresponding Service alarm in
GX Alarms
area will be GREEN – showing NO Fault.
Note: The Overall Status alarm will only show green if all of the generated alarms are
masked (or if all alarms are green).
In the figure above the alarm condition for (Service 2) “DL Output Power Low” actually
exists, while the masking prevents this condition from affecting the overall status of the
service and therefore the Service 2 LED in
GX
Alarms area is green.
Unmasked alarm
RED - Unmasked alarm reflects on
corresponding Service alarm and
Overall Status
Masked alarm
GREEN - Masked DL Output Power Low
alarm (for Service 2) alarm does not
reflect on corresponding Service alarm
in
GX Alarms
area.