User's Manual

MobileAccessGX Installation and Configuration Guide 39
5. In the DL Adjustment tab, perform DL adjustment manually to complete the commissioning
procedure.
Set the Target Max Pwr (Target Pout) value according to site planning requirements.
Default Target Max Power value is the maximum value per each band (e.g. 33 dBm for
700LTE band).
DL Output Power can be adjusted to a lower level (up to 10dB lower) as required.
Click the Adjust button.
Confirm that the adjustment procedure is successful (Adjust Result shows “Success”)
and verify actual readings of Adj. Date and DL Output Pwr .
If adjustment procedure fails, refer to the RF Parameters tab, click the Restore
button and perform adjustment again.
Figure 4-6: GX DL Adjustment Tab
Click to select
Target Max Power
Click to perform RF ad
j
ustment
according to Target Max Power
Verify successful results
Ad
j
ustment Date and Actual
DL Pwr readin
g