MobileAccessGX Installation and Configuration Guide 36
Service Alarms – displays specific alarms for each supported service.
Figure 4-3. GX Service Alarms Tab
Table 4-2. GX Service Alarms Description
Alarm
Description
Service SW
Service disabled by the User (via RF Parameters tab)
Adjustment
Adjustment for target DL Output Power
DL PA
PA Off
VSWR
Antenna disconnected (VSWR > 5:1)
DL Output Power High
DL Output Power > “Target Adjustment value” + 2dB
DL Output Power Low
DL Output Power < “Target Adjustment value” 1 15dB
Over Temperature
Ambient temperature inside the GX unit >65°C