User's Manual
Table Of Contents
- Preface Material
- Policy for Warrantee and Repair
- Safety Instructions
- Warnings and Admonishments
- Standards and Certification
- About this Guide and Other Relevant Documentation
- Table of Contents
- 1 Introduction to GX System
- 2 System Installation
- 3 Commissioning MA Head-End
- 4 Provisioning the MobileAccessGX
- Appendix A: System Specifications
- Appendix B: Ordering Information
- Appendix C: Site Preparation
MobileAccessGX Installation and Configuration Guide 32
Figure 3-15. OCH Alarms Display Area
4. Click the RF Parameters tab.
Figure 3-16: Base Unit RF Parameters Tab
Define the Interface Type – RF Source interface type (i.e. CMA RIU, Other)
If the DL Input power Low and DL Input power High alarms are RED, perform DL RF
adjustment:
o Low or High DL Input power indicates that the measured input power from
the BTS source is either lower or higher than the expected value:
When connected to RIU: Up to -20dBm
When connected directly to BTS (via passive interface): Up to 0dBm
o Adjust RF DL gain with Operational Att. (in 0-31 dB steps).