MobileAccessGX Installation and Configuration Guide 34
The GX Alarms are continuously displayed (to the left of the tabs). The monitoring and
configuration options are distributed over four tabs:
Module Info - device version and identification definitions
RF Parameters – service control options.
RF Adjustment – provides the adjustment options.
Service Alarms – used for masking redundant alarms
4.2 Basic Setup Procedure
To perform basic setup
1. Verify that the alarms show green in the following tabs:
GX Cabinet Alarms – displays system level alarms
Figure 4-2: Example of GX Alarms
The following table provides a description of the device alarms shown above.
Alarm
Description
Door Open
Enclosure door open
Optical Link Alarm
Low optical level from BU (link level < 56)
Fans Alarm
Faulty fans
Service 1/2/3
Summary of all port x / PA x monitored parameters
displayed in the
Service Alarms
sub-tab
Overall status
Calculated according to its active alarms –
corresponds to highest alarm level detected.
Table 4-1. GX Alarms Description