User's Manual
Table Of Contents
- Preface Material
- Policy for Warrantee and Repair
- Safety Instructions
- Warnings and Admonishments
- Standards and Certification
- About this Guide and Other Relevant Documentation
- Table of Contents
- 1 Introduction to GX System
- 2 System Installation
- 3 Commissioning MA Head-End
- 4 Provisioning the MobileAccessGX
- Appendix A: System Specifications
- Appendix B: Ordering Information
- Appendix C: Site Preparation
MobileAccessGX Installation and Configuration Guide 38
5. In the DL Adjustment tab, perform DL adjustment manually to complete the commissioning
procedure.
Set the Target Max Pwr (Target Pout) value according to site planning requirements.
Default Target Max Power value is the maximum value per each band (e.g. 33 dBm for
700LTE band).
DL Output Power can be adjusted to a lower level (up to 10dB lower) as required.
Click the Adjust button.
Confirm that the adjustment procedure is successful (Adjust Result shows “Success”)
and verify actual readings of Adj. Date and DL Output Pwr .
If adjustment procedure fails, refer to the RF Parameters tab, click the Restore
button and perform adjustment again.
Figure 4-6: GX DL Adjustment Tab
Click to select
Target Max Power
Click to perform RF adjustment
according to Target Max Power
Verify successful results
Adjustment Date and Actual
DL Pwr reading