ATTENTION!
Plate must be secured before installing the RAU5x unit!
If the bracket is not secured via the two middle safety rings, it must be secured with safety cables via the four remaining
safety rings.
A 3 in clearance is required from the surface above and below the RAU5x unit to allow for proper cooling airflow and for
heat dissipation.
The installer is responsible for accommodating the installation to the surface type.
2. (After plate is installed in ceiling) Pull down the Lift Bracket to a vertical position.
Figure 4-8. Lowering Lift Bracket
3. Referring to Figure 4-9, fit the four pins on the RAU5x underside into the wide end of Lift Bracketkeyholes and pull down
into narrow ends to lock in. Make sure that the RAU5x is secure.
Note: Lift Bracket captive screw must face the RAU5x connectors.
Figure 4-9.Mounting RAU5x onto Lift Bracket