User's Manual
Corning Restricted
Corning Optical Communications User Manual I CMA-482-AEN I Page 54
4.4.2.2 Optical Fiber Connection
Connect the optical fiber pair to RAU5 module LC APC optical connector (see Figure 4-25)
4.4.2.3 Main Power Connections
Note: The power consumption is the same for both RxU67 and RxU2325 modules.
RAU5x “MAIN POWER” (for RAU5x and RAU5x+RxU67 + RxU2325) DC input power connections (see Figure 4-26)
Connect the DC wire pair to the terminal block connector:
• Power input range: 37 to 57 VDC
• Wire size: 12-30 AWG
• Maximum consumption:
• RAU5x: 44.5 V; 48 W
• RAU5x + RxU67: 44.5 V; 73 W
NOTE: Connect the 2nd DC wire pair when there is not enough power!