4.4.2.4.4 For RAU5x Configurations that include GEMs
GEM Connections
1. Connect DC wire pair to the RAU5x Secondary Power DC input connector (see Figure 4-30):
Wire size: 12-30 AWG
Maximum consumption:
GEM: 4 W (RAU5x: 44.5 V ; 52 W; RAU5x + RxU/RxU2325 + GEM: 44.5 V; 78 W)
For 2 PoE ports of 802.3af: 43 V ; 31 W (Input range: 43 57 V DC)
For 2 PoE ports of 802.3af: 52 V ; 62 W (Input range: 52 57 V DC)
Figure 4-30. RAU5x Main and Secondary DC Input Connections
2. Connect fiber to SFP module ports as follows:
If using fiber terminated with LC APC (green), connect to pre-inserted APC to UPC adapters
If using fiber terminated with LC UPC connector (blue), remove pre-inserted APC to UPC adapters and connect directly
to SFP module ports.
3. Connect the A and B Ethernet ports to the PoE clients using Ethernet cables.
Note: A and B ports 10/100/1000 BASE-T with 802.3at compliant Power over Ethernet (PoE+) PSE ports.
Figure 4-31. GEM Interface Connections