User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 33 of 174
2.2.2 IHU Interfaces and Slots
The following figure shows the internal positions of IHU
Figure 4: IHU Interfaces and Slots
¾ IHU Slots
NOTE: If DCM cards are available, ensure they are installed in the IHU only (not in the HEU)!
Each IHU includes 14 slots supporting the following modules (see Figure 4: IHU Interfaces and Slots )
Remove blank panel and slide in the relevant module (chassis slots are 100% mistake proof):
x 1 HCM (for Standalone/Master HEU units) / (One) ACM (for Auxiliary HEU unit)
x 1 to 2 PSM – for single power supply installations, install the PSM in either (PSM) slot
x 1 to 8 RIM – no need to terminate unoccupied RIM slot (Slots 2-7)
x 1 to 2 DCM (Slots 8-9)
x 1 RIX (Slot 1)
x 1 OIX slot (Slot 14)
RIM Slots 1-8
OIX
PSM
HCM/ACM
RIX
DCM 2