UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 34 of 174
2.2.3 Mount the Chassis in a Rack
Notes:
One HEU supports connections to up to four IHUs
IHU chassis requires 4U rack height availability
Rack nuts and screws not provided
1. Determine the location of the HEU in the rack while considering additional HEU and IHU units and
the lengths of the available ERFC cable.
2. Refer to Error! Reference source not found. for an example planning the rack positions.
3. Secure the units’ rack ears to the rack frame as follows:
Insert two screws half-way into the rack frame.
Position the chassis on to the screws using the handles and the top and bottom half slots of
the rack ears.
Secure the unit in the rack via all applicable bracket holes using the appropriate rack nuts
and screws.
Installing Chassis in Rack