2.2.5.3 RIX 10 MHz Pilot Clock Connections
Notes:
This section is only relevant for configurations with additional IHU or HEU and OIU units.
The REF IN and REF OUT pilot clock ports must be connected in a closed loop.
Both RIX modules of each chassis must be connected.
The jumper cables are routed through the sides of the cable management tray and door.
Referring to the following Figure, use the QMA/QMA jumper cable (PCKC47 provided with each RIX) to
connect the REF OUT and REF IN ports of each of the RIX modules in the HEU chassis. See Error! Reference
source not found.
Note: use SFP+ from the approved list provided by Corning.
1. Remove the rubber stopper from the source port.
2. Push the SFP+ connector into the port, until it clicks (note that there is only one correct direction for
plugging-in).
3. Remove the white plug-protectors from the end of the SFP+ cable.
4. Plug the SFP+ cable into the D-MRU port until it clicks.
5. connect the other edge of the cable to the source unit
Figure 6 OIM SFP+ LC/UPC connection: Remove rubber stopper from port and from SFP+ Pluggable Transceiver and
insert the SFP+ Pluggable Transceivers (hot-pluggable optical transceiver module) into the port.
SFP+ Pluggable
Transceivers
SFP+ Cable