User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 47 of 174
2.3.3 Install the Modules in the Chassis
Note: For modules with ejectors (i.e. RIM, RIX and HCM/ACM) – verify that the ejectors are
completely open when inserting in dedicated slot and then push in until the module clicks in to
the backplane. See Figure 8: Module Captive Screws and Ejectors below, showing an example of
module type captive screws and ejectors.
Refer to the Figure 7: HEU Slots and Interfaces for module locations. Remove blank panel and slide in the
relevant module (chassis slots are 100% mistake proof):
x (One) HCM (for Standalone/Master HEU units) / (One) ACM (for Auxiliary HEU unit)
x (One to two) PSM – for single power supply installations, install the PSM in either (PSM) slot
x (Two) RIX modules
x (One to 12) RIM – no need to terminate unoccupied RIM slot
Referring to the following figure, secure the modules to the backplane by:
x Closing the ejectors (for relevant modules)
x Tightening the captive screws
Figure 8: Module Captive Screws and Ejectors