UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 49 of 174
2.3.4.3 RIX TO OIX Connections
Note: Each RIX module supports connections to up to two IHU.
1. Using the appropriate length ERFC cable (according to distance of available OIX port) connect the
HEU RIX module 9-Pin connector to the corresponding connector on the IHU OIX module.
2. Refer to TBD for schematic diagram of coax connections in a maximum HEU-OIU configuration of
4x4 where all HEU units are connected to all IHU units.
2.3.4.4 RIX Pilot Clock Connections
Referring to the following Figure (Shared Rack), use the QMA/QMA jumper cable (PCKC47 provided with each
RIX) to connect the REF OUT and REF IN ports of each of the RIX modules in the HEU chassis
Note:
The REF IN and REF OUT pilot clock ports must be connected in a closed loop as shown in
Error! Reference source not found.
Both RIX modules of each chassis must be connected
HEU
RIX
IHU
OIX