2.3.4.5 Management Connections
Notes:
One RJ45/RJ45 management cable is provided with each headend unit (i.e. HEU/IHU).
Up to 7 ACMs are connected to a single HCM, where the connection between the units is
using RJ45 cables.
x For HCM modules only - using the provided RJ45/RJ45 communication cable, connect the HCM
LAN port to the corporate LAN:
HCM LOCAL Port to ACM Port LOCAL Management Connection
x HCM to ACM Management Connections - using RJ45/RJ45 communication cables perform the
headend management connections according to the following:
x Referring to the above Figure - for configurations with one HCM and up to four ACM modules (e.g.
one HEU and four HIU units), directly connect as follows
From (any) HCM ….
To (any) ACM…
INTERNAL (TO ACM)
Port 1/2/3/4
INTERNAL (TO HCM)
Port 1/2/3/4
x Referring to Error! Reference source not found.- for configurations with one HCM and more than
four ACM modules (e.g. 4x4 HEU-OIU configurations) where there are only four available HCM
INTERNAL ports
Schematic Example of 4x4 Management Connections
2.3.5 Power ON
x For PSM-AC modules – connect supplied power cable (100-240 VAC) connector to the PSM input
connector and to the AC outlet and switch on.
x For PSM-DC modules – refer to Quick Start Guide provided with module for wiring pinout. Verify that
the Power Status LED on each PSM shows green. See Figure 13 for PS<-AC LED.