User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 57 of 174
2.5.6.2 Power
Use your selected power source (DC or AC); Connect the power-unit's cable to the DRU front panel.
2.5.6.3 Source (DCM)
Connect an SFP+ Pluggable Transceiver to each source port to be used:
1. Remove the rubber stopper from the SFP connector.
2. Remove the rubber stopper from the source port (Figure 9).
3. Push the SFP connector into the DCM port, until it clicks (note that there is only one correct
direction for plugging-in).
4. Remove the white plug-protectors from the end of the SFP cable.
5. Plug the LC/UPC SM DX cable into the DCM port until it clicks.
6. connect the other edge of the cable to the source unit
Figure 9 Remove rubber stopper from port and from SFP+ Pluggable Transceiver
2.5.6.4 Remotes
Remotes (i.e.: LRU, MRU, HRU): Connect an SFP+ Pluggable Transceiver to each remote port to be used:
1. Remove the rubber stopper from the SFP connector.
2. Remove the rubber stopper from the DRU-to Remote port (Figure 9).
3. Push the SFP connector into the remote port, until it clicks (note that there is only one correct
direction for plugging-in).
4. Remove the white plug-protectors from the end of the SFP cable.
5. Plug the LC/UPC SM DX cable into the remote port until it clicks.
6. connect the other edge of the cable to the remote unit