RF Safety
To comply with FCC RF exposure compliance requirement, adhere to the following warnings:
Warning! Antennas used for this product must be fixed mounted on indoor permanent structures, providing a separation distance
of at least 120 cm from all persons during normal operation and must not be co-located with any other antenna for meeting RF
exposure requirements.
Warning! Antenna gain should not exceed 12.5 dBi.
Warning! The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels
and non-environmental pollution during operation.
Compliance with RF Safety Requirements:
CAUTION! Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous
radiation exposure.
Power Requirements for DC Inputs
Warning! Only use a special DC supply cable with connector
Warning! Always keep DC IN connectors connected during the product operation
Warning! Disconnect all power from the equipment by means of an external circuit breaker before connecting or disconnecting the
DC IN connectors.
¾ RF Parameters
Frequency Range Name
Uplink
600-band 71
663-698 MHz
700L (Lower Band)- band 12
698-716 MHz
700U (Upper Band)-band 13
776-787 MHz
FirstNet (700)-band 14
788-798 MHz
800/850 -band 26
817-849 MHz
1900 (PCS)-band 25
1850-1915 MHz
EAWS-band 66
1710-1780 MHz
WCS -band 30
2305-2315 MHz
2500 -band 41
2496-2690 MHz (TDD)