2.7.9 Connect Power & POWER UP
The MRU PSM is located on the bottom right of the chassis front. The PSM type (AC/DC) is model dependent.
x Refer to section 2.4.7.1 for AC models.
x Refer to section 2.4.7.2 for DC models
2.7.9.1 AC models
WARNING! Approved power cable – the entire length of the power cable (or flexible cord) and
the insulation must be intact. The cable must be firmly connected to both the electrical plug and
the unit itself.
Standard plug – the use of a standard plug is mandatory. The use of a non-standard power plug
can cause electrocution! Also, plugging a non-standard plug into a standard socket that does not
correspond to the plugs’ shape, can damage the socket making it a safety hazard
AC Power Connection
Connect the MRU power connector to the AC power source using the provided AC power cable:
x Power input: 100-240 VAC/50-60 Hz
x Power consumption: 620 W (maximum)
x Maximum AC current consumption: 7 A