UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 127 of 174
5.1.3.1 Firmware
The Firmware tab allows the user to upgrade the firmware version of the system elements.
The HCM upgrade procedure consists of downloading the new software version, setting it as the “Active”
version, and restarting the HCM. The new software can be activated either immediately or at a more
convenient time as defined by the user. The procedures are performed via the Firmware submenu.
By default, Auto Sync option is enabled, hence the software of all installed devices at the site is updated to
the software version of the HCM. If this automatic update is not desired, the “Auto Sync” option can be set to
“OFF.”
The button can be used when a reboot is required.
¾ To upgrade the firmware version
1. In the main menu bar, click Æ
2. Download the new image file: In the "Install New Firmware" area (see image below), click the "SELECT
FILE" option and then browse for the required *.img file. For the latest build, refer to the Corning Everon™
6000 software release notes.
Once the required file is selected, click "LOAD". The download progress is indicated in the progress bar and
may take up to 10 minutes to complete. When the download is complete click "OK".
Note: Do not attempt to refresh the browser or perform any operation before download
procedure is complete.
3. Activate the new firmware version: After the download is complete, the new firmware version should
appear in the "Available in Standby" area: