User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 97 of 174
3.6 Remote Management
This section describes the configurations required for remote session access using Ethernet connection via
the LAN port.
At this point the system is ready to be connected to the LAN according to the instructions below.
For HCM modules only – using the provided RJ45/RJ45 communication cable, connect the HCM LAN port to
the corporate LAN:
The LAN port is set to a static IP address by default: 192.168.1.1; Subnet Mask: 255.255.0.0.
¾ To configure the HCM LAN port
1. IMPORTANT: Make sure the HCM LAN port is connected to the corporate LAN.
2. In the main menu bar, click Æ
3. Select the IPv4 LAN Port or IPv6 LAN Port tabs and click the button.
4. The LAN port is set to a static IP address, by default: 192.168.1.1; Subnet Mask: 255.255.0.0.
You may change the static IP address, subnet mask and default gateway manually to legal values.
Note: make sure the values youenter in the above fields aren't used by other system elements,
and are different than the default values.
Multiple ACM units may be
connected to a single HCM via the
INTERNAL ports for management
purposes.
Only HCM modules should be
connected to the corporate LAN.
ACM modules are connected via
the HCM modules.