User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 162 of 174
¾ Low Band LRU-Low power Remote Unit
¾ End to End System Performance
¾ Headend to Digital Low power Remote Unit
RF Specifications
Frequency Range
Name
600
700L & 700U &
FirstNet
800/850
Frequency Range
Uplink
MHz
663-698
698-716
777-798
817-849
Downlink
617-652
728-746
746-768
862-894
Max. Operating Bandwidth-Non-contiguous
MHz
Full Band
Instantaneous Bandwidth
MHz
35
18
21
32
Downlink Output Power (LRU)
dBm
20
20
20
Attenuation Adjustable Range (1dB step)
dB
0-20
Pass Band Ripple (p-p)
dB
≤ 4
≤ 4
≤ 4
≤ 4
Channel Bandwidth
MHz
5/10/15/20
Uplink Noise Figure (typical)
dB
12
Uplink IIP3 (typical)
dBm
-14
VSWR
≤ 1.8
EVM (256 QAM) (TM3.1A @ Rated power)
%
< 3.5
Spurious Emission
3GPP TS 36.106/25.106; 3GPP TS 38.104
V15.5.0 (sections 6; 7)
Electrical Specifications
Power Consumption
Watt
70
DC voltage
DC
37-56
Interfaces and Mechanical
CPRI Port
1, SFP+ 10.1Gbps
Antenna Ports
2, 4.3-10 female
Dimension (W x H x D)
Inch
(mm)
9.84 x 10.63 x 2.75 (250 x 270 x70)
Weight
Lbs
(Kg)
1
3 (6)
Mounting and installation
Wall, ceiling and pole mount options
Cooling
Convection
Environmental
Operational Temperature
°F (°C)
-40° to 131° (-40° to 55° )
Outdoor installation (Ingress Protection)
IP 66
*Technical spec subject to change without notice