User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 1-MAR-2021 - clear of comments| March 2021 |Page 167 of 174
¾ HRU -High-Power Remote Unit
¾ System performance (Head End to High power Remote Unit)
RF
Frequency Range Name
600
700L & 700U
& FirstNet
800
/850
1900
EAWS
WCS
2500
Frequency Range
Uplink
MHz
663-
698
698-
716
777-
798
817-
849
1850-
1915
1710-
1780
2305-
2315
2496
-
2690
Downlink
617-
652
728-
746
746-
768
862-
894
1930-
1995
2110-
2180
2350-
2360
Max. Operating
Bandwidth
-Non-
contiguous
MHz
Full Band
Instantaneous Bandwidth
MHz
35
18
21
32
65
70
10
100
Downlink Output Power
dBm
43
43
43
43
43
43
43
Attenuator Adjustable
Range (1dB step)
dB
0
-20
Pass Band Ripple (p-p)
dB
≤ 4
Channel
Bandwidth
MHz
5/10/15/20
5/10/15/20
for 4G
40
or 60
for 5G
Uplink Noise Figure
(typical)
dB
6
Uplink IIP3 (typical)
dB
-20
VSWR
≤ 1.8
EVM (256 QAM)
(TM3.1A@ Rated power)
%
< 3.5
Spurious Emission
3GPP TS 36.106/25.106; 3GPP TS 38.104 V15.5.0 (sections 6; 7)
Electrical Specifications
Power Consumption
(Typical)
Watt
OEU (Optical Expansion Unit) –connected
to RFU’s
50
RFU (RF Unit) – MIMO 2:2 for the bands
600,700,800/850,1700.1900,2300,2500TDD
220
AC voltage
AC
100-240