User's Manual

User Manual v1.0
UM - Everon 6000 DAS - 14-APR-2021 - clear of comments.docx| March 2021 |Page 111 of 202
4. Session Access and first time settings
Once all the system elements are installed, the system administrator can log into the system GUI and
perform initial configurations.
It is recommended to begin working with the Corning® Everon™ 6000 by following these steps:
1.
Open a local session to the HCM
, see Open a Local Session section 4.1.
2.
Configure the LAN IP settings
to allow remote access, see Remote Management section 4.2
3.
Perform the initial configurations
using the system GUI, see Commissioning, chapter 5
4.1 Open a Local Session
Below are the instructions for opening a local management session, to perform basic system configurations
via the system GUI.
¾ To Open the system GUI
1. Connect a computer (i.e., laptop) to the HCM LOCAL port via an RJ45 Cat 5 Ethernet cable, as shown
below:
Notes:
* The LOCAL port is set to a static IP Address by default: 172.16.1.1; Subnet Mask: 255.255.0.0.
Your laptop/tablet network parameters must be set to match the subnet of the default IP
address.
* The laptop/tablet IP address must be different than the LOCAL port IP address.
2. Set up your laptop/tablet network parameters by following the steps below (the steps may vary
slightly depending on the OS version used):
Connect the computer to
the LOCAL port